LI Series In-Line Liquid Samplers

Direct In-Line Representative Sampling Systems

LI Series In-Line Liquid Samplers

Spirare Energy's LI Series In-Line Liquid Samplers are designed for direct installation into active process pipelines, flanged vessel nozzles, or reactor outlets. By extracting grab samples directly from the moving fluid stream, the LI Series eliminates long sample takeoff tubing, minimizes lag time, and completely avoids stagnant dead legs, delivering instantaneous representative liquid samples.

Operating at media pressures below 8 Bar.g (with high-pressure custom valve ratings available upon request) and vapor pressures below 0.7 Bar.g, the LI Series utilizes a spring-loaded deadman safety handle and a sealed septum bottle interface. Available in robust SS 316/316L, Hastelloy, Monel, and specialized PTFE-lined valves for highly corrosive acids and aggressive chemical media, the LI Series guarantees zero operator exposure and total environmental emission containment.

Offered in three specialized configurations—In-Line Ball Type (LI1), In-Line Needle Type (LI2), and In-Line Needle with Continuous Purging (LI3)—Spirare Energy configures tailored in-line liquid sampling stations with flanged, NPT, or compression connections for chemical processing, refining, petrochemical, and pharmaceutical plants globally.

Technical Data & Configurations

Sampler Specifications & Models

Explore complete technical specifications, available options, and the three specialized LI Series in-line configurations engineered for direct process line grab sampling.

Sampler Specifications

Design Limits

Operating Pressure

Below 8 Bar.g (Standard)

Standard in-line systems operate below 8 Bar.g. Higher pressure rated custom valves and flanges available upon request.

Vapor Pressure

Below 0.7 Bar.g (10 psig)

Engineered for liquid media having vapor pressure below 0.7 Bar.g. Eductor collection prevents fluid boiling during draw.

Material of Construction (MOC)

SS 316 / PTFE Lined (Options)

Standard SS 316/316L. Exotic options: Hastelloy C-276, Monel 400, Duplex, and specialized PTFE-lined valves for corrosive acids.

Process Connections

1/4" OD, NPT, Flange (Standard)

Available in compression tube fittings, female NPT, or ANSI/ASME Class 150/300/600/DIN/JIS flanged pipeline connections.

Sleeve & Retainer Assembly

100CC, 150CC, 250CC, 500CC, 1000CC

Heavy-duty protective sleeve with positive bottle retention, and needle guide shroud.

Sample Bottle Sizes & Types

100 cc, 150 cc, 250 cc, 500 cc, 1000 cc etc.

Borosilicate glass laboratory bottles with PTFE/elastomer septum caps and plastic shatter-guard coatings.

Options Available & Custom Accessories

Mounting Plate & Enclosure Cabinets

SS 304/316 mounting plate, weather-proof IP protective cabinet with lockable door and viewing window.

Spring Return Handle (Deadman Lever)

Fail-safe spring return handle that automatically isolates process line when released by operator.

Floor / Pipe Stand Assembly

2" NB stanchion pipe Mounting Stand in carbon steel (galvanized/powder-coated) or SS 304/316. (Optional)

PTFE Lined Valves for Corrosive Media

Specialized PTFE/PFA lined valve and wetted components for handling aggressive acids and corrosive chemicals.

Automatic Sampling Actuation

Pneumatic or electric actuators with sequence timer controller for automated remote sampling cycles.

High Pressure Custom Valve Ratings

Custom valves and heavy-duty sampling assemblies engineered for demanding process lines.

Assembly & P&ID Schematic
Direct In-Line Flow
LI Series In-Line Liquid Samplers Detailed Schematic and P&ID
Process Flow:Sample In → In-Line Valve → Sample Out → Vent
Installation:Direct Pipeline Flange / Threaded Mounting
Corrosion Option:PTFE / PFA Lined Valve
Configurations

In-Line Liquid Sampling (LI1 – LI3)

Select an engineered in-line configuration based on your valve mechanism, precision throttling, and purging requirements.

Model: LI1Direct In-Line Ball Valve Grab Sampling

In-Line Ball Type On-Off Sampling

Direct pipeline mounting with high-integrity ball valve mechanism and spring-return deadman lever for rapid, full-flow on/off representative grab sampling from active process lines.

Purge / Flush Mode:Direct In-Line Process Flow with Standard Vent Routing
Recommended Application:General chemical and hydrocarbon process piping, slurries, and media requiring unrestricted flow.

Custom engineered skids available on request

ModelSystem Type & DescriptionPurging / OperationAction
LI1
In-Line Ball Type On-Off Sampling
Direct pipeline mounting with high-integrity ball valve mechanism and spring-return deadman lever for rapid, full-flow on/off representative grab sampling from active process lines.
Direct In-Line Ball Valve Grab Sampling
Direct In-Line Process Flow with Standard Vent Routing
LI2
In-Line Needle Type On-Off Sampling
Precision in-line needle valve control enabling metered, controlled dispensing rate into the septum bottle for hazardous or pressurized process fluids directly at the pipeline point.
Throttled In-Line Needle Valve Sampling
Needle Dispensing with Dedicated Vent / Flare Header Connection
LI3
In-Line Needle and Continuous Purging Sampling
Advanced in-line configuration combining precise needle sampling with continuous process bypass circulation and dedicated inert Nitrogen (N2) needle purging to eliminate residue build-up.
In-Line Needle + Nitrogen Inert Purge
Continuous Process Circulation + N2 Inert Gas Needle Purging
Engineering Tools

PROCESS APPLICATION CONFIGURATOR

Select your desired application to configure the ideal engineering pathway and receive a tailored quotation.