Spirare Energy's LV Series Fixed Volume Liquid Samplers are engineered for high-pressure and critical process applications where liquid operating pressures exceed 8 Bar.g, and an exact, predetermined sample volume must be safely extracted without exposing plant personnel or the surrounding atmosphere to volatile compounds.

Featuring an integrated fixed-volume chamber isolated by high-integrity switching valves, the LV Series captures an exact volumetric sample of process fluid under full line pressure. Once isolated from the active process line, the trapped sample is safely collected into a sealed septum glass bottle, eliminating overfilling risks and operator exposure, meanwhile fixed sample cylinder is purged via a dedicated Nitrogen (N2) purge connection.

Engineered for liquids with vapor pressures below 0.7 Bar.g (10 psig), the LV Series is fabricated with standard wetted components in SS 316/316L (with exotic alloys like Hastelloy and Monel available). With specialized configurations including threaded connections (LV1), continuous fast-loop needle purging (LV2), and thermal heating/cooling tracing (LV3), Spirare Energy provides robust, custom-engineered sampling solutions for high-pressure refining, petrochemical, and specialty chemical facilities worldwide.

Technical Data & Configurations

Sampler Specifications & Models

Explore complete technical specifications, available options, and the specialized LV Series fixed-volume configurations engineered for high-pressure closed-loop sampling.

Sampler Specifications

Design Limits

Operating Pressure

Above 8 Bar.g (High Pressure)

Specifically engineered for high-pressure liquid process streams requiring metered fixed-volume chamber isolation before dispensing.

Vapor Pressure

Below 0.7 Bar.g (10 psig)

Suitable for liquids with low vapor pressure.

Material of Construction (MOC)

SS 316 / SS 316L (Standard)

Standard SS 316/316L wetted parts. Exotic options: Hastelloy C-276, Monel 400, Duplex 2205, Super Duplex, Inconel 625.

Fixed Volume Chamber Sizes

50cc, 100cc, 200cc, 450cc, 950cc & higher

Fixed-volume chamber size with glass sample bottles to guarantee exact volumetric sample collection.

Sleeve & Retainer Assembly

Rugged protective sleeve, positive bottle retention lock.

Process Connections

1/4" OD / NPT (Standard)

Standard 1/4" compression tube fittings or female NPT. Options: 3/4", 1/2", Flanged ANSI Class 150/300/600/900/1500.

Options Available & Custom Accessories

Mounting Plate & Enclosure Cabinets

SS 304/316 mounting plate, weather-proof IP protective cabinet with lockable door and viewing window (Optional).

Floor / Pipe Stand Assembly

2" NB stanchion pipe or MS / carbon steel (galvanized/powder-coated) or SS 304/316 mounting stand.

Nitrogen (N2) Purge Connection

Integrated N2 purge complete with pressure indicator (PI), check valve, and purge regulator.

Heating & Cooling Jackets

Steam tracing jackets, electrical heating blankets, or cooling heat exchangers for temperature-critical fluids.

Spring Return Deadman Handles

Fail-safe spring return handles that automatically isolate the process lines when released.

Automated Sampling Actuation

Pneumatic or electric actuators with sequence timer controller for automated fixed-volume sampling cycles.

Assembly & P&ID Schematic
Fixed Volume Architecture
LV Series Fixed Volume Liquid Samplers Detailed Schematic and P&ID
Process Flow:Sample In → Chamber → Sample Out → Purge N2 (PI)
Chamber Design:Fixed Volume Pressure Cylinder
Discharge Mode:N2 Purge Assisted Septum Bottle Filling
Configurations

Liquid Sampling Systems (LV1 – LV3)

Model: LV1Standard Fixed Volume Grab Sampling

Fixed Volume Threaded Connection Type

Standard fixed-volume closed-loop sampling utilizing threaded process connections with manual sequential valve isolation to trap an exact volume and safely discharge it into the septum bottle.

Purge / Flush Mode:Standard Vent / Flare Line Routing with Manual Depressurization
Recommended Application:High-pressure non-flashing chemical and hydrocarbon media requiring metered volume extraction.

Custom engineered skids available on request

ModelSystem Type & DescriptionPurging / OperationAction
LV1
Fixed Volume Threaded Connection Type
Standard fixed-volume closed-loop sampling utilizing threaded process connections with manual sequential valve isolation to trap an exact volume and safely discharge it into the septum bottle.
Standard Fixed Volume Grab Sampling
Standard Vent / Flare Line Routing with Manual Depressurization
LV2
Fixed Volume Continuous Needle Purge Type Sampling
Maintains continuous process circulation across the fixed-volume chamber while integrating inert Nitrogen (N2) needle purging to flush residual liquid and clear dispensing needles post-sampling.
Fast-Loop Bypass + Nitrogen Needle Purge
Continuous Bypass Loop + Dedicated N2 Needle Inert Gas Purge
LV3
Fixed Volume Heating / Cooling Type Sampling
Engineered with integrated steam tracing, electrical heating jackets, or sample cooling heat exchangers to maintain exact fluid temperatures and prevent freezing, waxing, or viscous media.
Thermally Conditioned Fixed Volume Sampling
Thermal Jacket Tracing + N2 Inert Gas Flushing